BuildX Load Generator

by aedo construction

NSCP 2015 · wind, diaphragm, and seismic loads, ready to paste into STAAD

Wind Loads

Components & Cladding · NSCP 2015 §207E · used for purlins, trusses/girts, and facade panels — elements that resist wind locally rather than as part of the main lateral system.
1

Element / Member

What is this wind pressure being applied to?

Purlin
Roof C&C member — outputs combined DL + Roof LL + WL line load
Truss / Girt
Larger tributary roof C&C member — reuses purlin reaction
Glass Facade / Curtain Wall
Wall C&C panel/mullion — pressure only, no DL/LL
2

Geometry & Loads

Fields change based on the element selected in Step 1

Wind pressure — required
Roof slope — sets slope band & roof LL pitch reduction
Dead load materials
Zone reference — building footprint, used only to compute edge/corner zone width "a" (min of the two dimensions, per NSCP — not tied to purlin orientation). Doesn't change any pressure value; only tells you how far from the eave/corner Zone 2/3 extends, so you know which zone to apply to a given purlin's actual position
3

Location

Province, city, or municipality

Use a custom wind speed
Skips location lookup — enter any V (kph), same for every category
4

Risk / Occupancy Category

NSCP 2015 §103 — determines wind map

5

Exposure Category

Terrain roughness upwind

Exp B
Urban / Suburban
Exp C
Open Terrain
Exp D
Flat / Water
6

Enclosure Classification

Determines internal pressure coefficient GCpi (NSCP Table 207A.11-1)

Enclosed
GCpi = ±0.18
Partially Enclosed
GCpi = ±0.55
Open
GCpi = 0
7

Topographic Effects (Kzt)

Wind speed-up over an isolated hill, ridge, or escarpment — NSCP 2015 §207A.8

Consider wind speed-up over hills or escarpment
Off = flat/gently-rolling terrain, Kzt = 1.0 (the default in STAAD and most projects)
Kzt = 1.00 (flat terrain)

Result